Page 35 - 理化检验-物理分册2024年第三期
P. 35

DOI : 10.11973 / lh jy -wl202403006

                               不同晶粒度测量方法的结果比对





                 武   甲 ,杨荣光 ,周志超 ,雷   娜 ,赵乃胜 ,杨艳龙 ,张海燕 ,谢新艳 ,沈   洁 ,王明辉                                1








                                                                   1
                       1
                                                                                              1
                                                           1
                                                  1
                                                                            1
                                2
                                         1
                                                                                     1
                          ( 1. 北京首钢股份有限公司,迁安 064404 ; 2. 北京首钢吉泰安新材料公司,北京 102206 )






                    摘   要: 分别采用截点法和面积法对 GB / T6394 — 2017 标准图谱中 5 张第I系列评级图进行晶
                 粒度测量, 并对结果进行比对分析。结果表明: 采用不同测量方法得出的晶粒度级别存在偏差; 以
                 矩形面积法结果为基准进行比对时, 使用截点法的横纵测量网格线进行截点计数得到的结果最合
                 理, 精确度在 0.15 级范围内。在进行等轴晶粒度测量时, 使用截点法更简便、 快捷, 建议采用截点
                 法的横纵测量网格来测量晶粒度。
                    关键词: 晶粒度;截点法;面积法;测量网格




                    中图分类号: TB31 ; TG115.2    文献标志码: A    文章编号: 1001-4012 ( 2024 ) 03-0023-04

                   Com p arisonofresultsfromdifferent g rainsizemeasurementmethods
                                                                                  ,

                                              ,
                                             2
                                                           1
                              1
                                                                                 1
                                                                   1
                        WUJia , YANGRon gg uan g ZHOUZhichao , LEINa , ZHAONaishen g YANGYanlon g 1 ,

                                                1
                                                                     1
                                                            1
                                    ZHANGHai y an , XIEXin y an , SHENJie , WANG Min g hui 1

                                       ( 1.Bei j in gShou g an gCo. , Ltd. , Qian ’ an064404 , China ;

                               2.Bei j in gShou g an gGitaneNew MaterialsCo. , Ltd. , Bei j in g102206 , China )


                     Abstract : Theg rainsizeofthefiveI-seriesratin gg ra p hsintheGB / T6394-2017standards p ectrum was

                 measuredusin g theinterce p tmethodandtheareamethodres p ectivel y , andtheresultswerecom p aredandanal y zed.

                Theresultsshowthatthereweredeviationsintheg rainsizelevelsobtainedusin gdifferentmeasurementmethods.

                 Whencom p arin gwiththeresultsoftherectan g ulararea method , themostreasonableresultwasobtained when

                usin g thehorizontalandverticalmeasurementg ridlinesoftheinterce p tmethodtocountcutoffp oints , withan

                accurac ywithintheran g eof0.15.When measurin ge q uiaxedg rainsize , usin gtheinterce p t method was more

                convenientandefficient.Itwasrecommendedtousethehorizontalandverticalmeasurementg ridoftheinterce p t

                 methodtomeasureg rai nsize.


                     Ke y words : rainsize ; interce p tmethod ; areamethod ; measurement g rid
                               g
               金属材料的晶粒度对其在室温及高温下的力学                            对于批量生产的检验, 比较法的测量精度已足够; 对
            性能有决定性影响, 晶粒尺寸细化是钢铁材料强化                            于精度要求较高的材料, 可以使用面积法和截点法
            的重要方法之一。一般情况下, 晶粒尺寸越小, 材料                          测量其晶粒度      [ 1-2 ] 。
            的强度和硬度越高, 韧性越好             [ 1-3 ] 。因此, 在金属性           近期在晶粒度标准比对试验过程中, 发现采用
            能分析中, 晶粒尺寸测量结果的准确性至关重要。                            不同晶粒度测量方法或者采用面积法( 测量网格不


                 一般依据 GB / T6394 — 2017 《 金属平均晶粒度              同) 对晶粒度进行测量时, 得到的结果均存在偏差,

            测量 方 法》 对 钢 铁 产 品 进 行 晶 粒 度 测 量。 GB / T            且每种方法的测量精度不同。笔者进行了一系列晶
            6394 — 2017 提供了 3 种平均晶粒度测量方法, 分别                   粒度测量试验, 分析了各方法的精度偏差, 找出了最
            为: 比较法, 面积法和截点法。对于等轴晶单相组织                          佳晶粒度测量方法。
            试样, 使用比较法测量材料的晶粒度既方便又实用,
                                                              1  试验方案

                收稿日期: 2023-05-30                                   在 GB / T6394 — 2017 标准图谱中选取 5 张均

                作者简介: 武 甲( 1983- ), 男, 助理工程师, 主要从事金相检测
                                                               匀分布的等轴晶粒图片, 结合图像分析系统, 对这 5
            工作, 148116095@ qq .com
                                                                                                         2 3