Advanced Search
    LI Zhao-hui, GAI Xiu-ying, SUN Ji-hong, GUAN Xue-ming. ANALYSIS OF BROKEN REASON OF THE HOLLOW WATER-COOLING WIRE IN THE GENERATOR UNIT STATOR[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2007, 43(9): 480-482.
    Citation: LI Zhao-hui, GAI Xiu-ying, SUN Ji-hong, GUAN Xue-ming. ANALYSIS OF BROKEN REASON OF THE HOLLOW WATER-COOLING WIRE IN THE GENERATOR UNIT STATOR[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2007, 43(9): 480-482.

    ANALYSIS OF BROKEN REASON OF THE HOLLOW WATER-COOLING WIRE IN THE GENERATOR UNIT STATOR

    • The fracture surface and the microstructure and the mechanical properties of the hollow water-cooling wire in the generator unit stator were studied by scanning electron microscope (SEM) and optical microscope and tensile testing. The result showed that the hollow water-cooling wire was fatigue fracture,which caused by friction because of loosed hollow water-cooling wire.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return