Advanced Search
    DU Chen-yang. Rupture Analysis of Boiler Water-wall Tube[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2010, 46(7): 456-458.
    Citation: DU Chen-yang. Rupture Analysis of Boiler Water-wall Tube[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2010, 46(7): 456-458.

    Rupture Analysis of Boiler Water-wall Tube

    • Rupture reason of boiler water-wall tube was analyzed by means of chemical composition analysis, mechanical properties testing, macroscopic and microscopic examination. The results showed that the rupture of the water-wall tube was as a result of material performance degradation caused by pearlite spheroidization under overheating condition.