Advanced Search
    XIAO Zhe-dong. Analysis and Evaluation on Measurement Uncertainty of Apparent Porosity of Silica Refractory Bricks[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2011, 47(7): 428-429.
    Citation: XIAO Zhe-dong. Analysis and Evaluation on Measurement Uncertainty of Apparent Porosity of Silica Refractory Bricks[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2011, 47(7): 428-429.

    Analysis and Evaluation on Measurement Uncertainty of Apparent Porosity of Silica Refractory Bricks

    • According to GB/T 2997-2000, the apparent porosity of silica refractory bricks were measured and calculated. The measurement uncertainty component which affecting apparent porosity measurement was analyzed and evaluated. The various components of the measurement uncertainty were computed and synthetic, finally, the measurement uncertainty results of apparent porosity of silica refractory bricks were: πa=20.2%, U=0.2%, k=2.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return