Advanced Search
    ZHU Zheng, WANG Chun-liang. Analysis on Fracture Reason of Rotor Shaft of Transmission Device[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2015, 51(1): 65-68.
    Citation: ZHU Zheng, WANG Chun-liang. Analysis on Fracture Reason of Rotor Shaft of Transmission Device[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2015, 51(1): 65-68.

    Analysis on Fracture Reason of Rotor Shaft of Transmission Device

    • The fracture reason of rotor shaft of transmission device was analyzed by optical direct reading spectrometer, optical microscope, scanning electron microscope (SEM) and election diffraction spectrometer (EDS). The results showed that the cracks were caused by stress corrosion, and expanded in the form of fatigue, until the fracture appeared in rotor shaft.
    • loading