Advanced Search
    XU Kai, GU Shuchao, ZHU Leiyuan. Reasons for bearing fracture of flue gas heat exchanger in thermal power generation unitJ. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2025, 61(12): 72-76. DOI: 10.11973/lhjy-wl240220
    Citation: XU Kai, GU Shuchao, ZHU Leiyuan. Reasons for bearing fracture of flue gas heat exchanger in thermal power generation unitJ. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2025, 61(12): 72-76. DOI: 10.11973/lhjy-wl240220

    Reasons for bearing fracture of flue gas heat exchanger in thermal power generation unit

    • The cylindrical roller bearing of the flue gas heater in the desulfurization system of a certain coal-fired power generation unit broke. The reasons for bearing fracture were analyzed using macroscopic observation, chemical composition analysis, scanning electron microscopy analysis, metallographic examination, hardness testing. The results show that there were obvious casting defects such as looseness, inclusions and pores in the bearing retaining frame. The angle of the bearing retaining frame did not transition smoothly, resulting in stress concentration at the corner and the initiation of microcracks. As the cracks continued to propagate, the bearing retaining frame broke, which led to abnormal stress and fracture of the bearing steel ring. Improper selection of bearing lubricating oil further accelerated the fracture process of the bearing.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return