WANG Qingfeng. Causes of leakage of final reheater G102 steel pipe in thermal power plant[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2023, 59(10): 52-57. DOI: 10.11973/lhjy-wl202310013
Citation: WANG Qingfeng. Causes of leakage of final reheater G102 steel pipe in thermal power plant[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2023, 59(10): 52-57. DOI: 10.11973/lhjy-wl202310013

Causes of leakage of final reheater G102 steel pipe in thermal power plant

More Information
  • Received Date: June 18, 2023
  • Leakage occurred to the G102 steel pipe of the final reheater in a large thermal power plant. The causes of leakage were analyzed by means of macroscopic observation, chemical composition analysis, metallographic examination, scanning electron microscopy and energy spectrum analysis, and mechanical property test. The results show that the G102 steel pipe section of the final reheater had been running for 160,000 hours, and the structure was aging and the performance was seriously degraded. The oxide skin of the inner and outer walls of the G102 steel pipe section affected the heat exchange, increased the temperature of the metal wall, accelerated the aging of the material structure and the deterioration of the performance, and finally made the G102 steel pipe reach the later stage of creep life and leak. The design and structural factors also accelerated the aging and performance degradation of the material. Finally, some suggestions were put forward for the safe and stable operation of the G102 steel pipe of the final reheater.
  • [1]
    钟伟,周宇杰,王泽烨,等.新型电力系统安全稳定运行分析[J].湖南电力,2022,42(3):29-34.
    [2]
    龚秋文,刘课秀,马括,等.某亚临界机组锅炉分隔屏过热器爆管原因[J].理化检验(物理分册),2022,58(12):68-72.
    [3]
    张鸿武,杨东旭,岳增武,等.某电厂锅炉高温过热器管泄漏原因[J].理化检验(物理分册),2020,56(12):67-70.
    [4]
    刘杰,赵永峰,刘翔,等.600MW超临界锅炉TP347H高温过热器管爆管的显微分析[J].热加工工艺,2020,49(2):159-162.
    [5]
    罗家华.热处理工艺对12Cr2MoWVTiB(102钢)组织和性能的影响[D].长沙:中南大学,2006.
    [6]
    楼玉民,杨点中,胡洁梓.钢102材料运行后的组织性能变化及原因分析[J].浙江电力,2013,32(6):51-53.
    [7]
    沈非,郑国,张雪,等.12Cr2MoWVTiB钢服役过程中组织与性能变化的研究[J].理化检验(物理分册),2001,37(11):466-469.
    [8]
    江范清,胡文龙,奚杰峰.600MW锅炉12Cr1MoV末级再热器管失效原因分析[J].热加工工艺,2016,45(4):255-257.
    [9]
    黄鑫,丁克勤,赵军.电站锅炉过热器管失效规律研究[J].失效分析与预防,2012,7(4):217-220.
    [10]
    郭岩,周荣灿,侯淑芳,等.617合金760℃时效组织结构及力学性能分析[J].中国电机工程学报,2010,30(26):86-89.
    [11]
    卢书媛,王卫忠,俞璐,等.锅炉过热器管爆裂原因分析[J].理化检验(物理分册),2016,52(11):807-810,814.
    [12]
    郑士华,李惠琳.12Cr2MoWVTiB(102)锅炉钢管的质量问题[J].发电设备,1996,10(9):19-23.