    XUAN Dongsheng, ZHANG Libing, SHEN Xian, LIU Haibo, ZHANG Peng, WANG Hui. Failure Analysis on Fracture of Adjust Stud in Metro Pantograph[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2018, 54(9): 676-679,691. DOI: 10.11973/lhjy-wl201809013
    Citation: XUAN Dongsheng, ZHANG Libing, SHEN Xian, LIU Haibo, ZHANG Peng, WANG Hui. Failure Analysis on Fracture of Adjust Stud in Metro Pantograph[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART A:PHYSICAL TESTING, 2018, 54(9): 676-679,691. DOI: 10.11973/lhjy-wl201809013

    Failure Analysis on Fracture of Adjust Stud in Metro Pantograph

    • The fracture failure of the adjust stud in metro pantograph happened during runtime, the fracture reasons of the adjust stud in metro pantograph were analyzed by means of chemical composition analysis, fracture macro and micro analysis, metallographic examination, mechanical property test and so on. The results show that the surface of threaded connection pair at the end of the nut was worn and corroded during runtime, and the adjust stud was subjected to alternating bending load, which resulted in corrosion fatigue fracture of the stud.