高级检索

    穿条式隔热型材的水中浸泡试验与湿热试验

    Water Immersion and Damp Heat Test of Thermal Barrier Profiles with Insertion Methodology

    • 摘要: 对穿条式隔热型材的水中浸泡与湿热试验按照即将发布的隔热型材新标准中规定的试验方法进行了大量的试验、计算和分析。结果表明:两种试验后的横向抗拉特征值的降低量基本都没有超过30%,说明了新标准中提出的要求是完全可以达到的。

       

      Abstract: A mass of test datas about water immersion test and damp heat test of the thermal barrier profiles with insertion methodology were calculated and analyzed. The results showed that the reducing values of transverse tensile eigenvalue were not over 30% basically, which can absolutely reach the requirement of the new standard.

       

    /