S355J2+N钢板拉伸试验测量结果的不确定度评定
Uncertainty Evaluation of Tensile Test Result for S355J2+N Steel Plate
-
摘要: 根据JJF 1059-1999标准,分析了S355J2+N钢板在拉伸试验过程中设备、量具、试验人员、数值修约等因素对试验结果的影响,并对其进行了不确定度评定。结果为: Urel(ReL)=0.9%,Urel(Rm)=0.9%,Urel(A)=0.4%;表明S355J2+N钢板的拉伸检测过程受控正常。Abstract: According to JJF 1059-1999,every factor of S355J2+N steel plate had been tested. Calculating the effects of different factors such as equipment,measuring tool,operator,rounding of numberical values,and the uncertainty of testing was also analyzed,the result of the relative measurement uncertainty was Urel(ReL)=0.9%,Urel(Rm)=0.9%,Urel(A)=0.4%. It was shown that the tensile test procedures were under control normally.