    • 摘要: 某台680t/h电站锅炉高温过热器最近发生两起爆管事故, 通过对爆管样管进行宏观检验、化学成分分析和金相检验判断爆管的根本原因。结果表明: 由于长时间超温运行导致管子早期蠕变引起爆管, 并采取了有效的预防措施。

       

      Abstract: Bursting of high temperature superheater tubes of 680t/h power station boiler coccured twice re-cently, and macroscopic examination, chemical compositions analysis and metallographic examination were investiga-ted to find the casuse, the results showed that the failure was due to overheat which led to primary creep, then someeffective prevention was taken.

       

    /