    关于热模拟试验机压缩试验中温度弹跳的分析

    Analysis of Temperature Jumping in Compression Test by Thermal Simulator

    • 摘要: 在Gleeble3500热模拟试验机的圆柱体单向压缩试验过程中, 由于多种原因导致试样在压缩过程中显示的温度瞬间升高, 通过在热模拟试验机上进行圆柱体单向压缩试验, 采用不同的试验方案, 分析了压缩过程中, 由于热电偶间距变大和试样的电阻变小这两个因素对温度检测结果的影响。

       

      Abstract: During the compression cylinder one-way on Gleeble3500 thermal simulator, the temperature increased at the moment of compressing for many reasons. By different test cases of compressing the cylinder with Gleeble3500 thermal simulator, analyzing the effects of larger space between the thermocouples and the decreasing of the workpiece resistance on the temperature detection.

       

    /