高级检索

    9Cr18不锈钢计量活门磁粉检测磁痕分析

    Indication Analysis on Magnetic Particle Testing for Metering Valve of 9Cr18 Stainless Steel

    • 摘要: 针对9Cr18不锈钢计量活门在磁粉检测过程中出现的线性磁痕显示,结合微观检验对磁痕形成的原因进行了分析。结果表明:组织中存在的铬偏析条带是造成磁粉探伤时出现线性显示的原因。

       

      Abstract: The linear indication was detected on the surface of metering valve of 9Cr18 stainless steel in magnetic particle testing process, and the reason of linear indication was analyzed by microstructure examination. The results showed that the indication was caused by chromium segregation.

       

    /

    返回文章