    • 摘要: 详述了安装在JEM-2100高分辨透射电镜上的 Olympus CCD 图像采集系统的使用技巧和参数设置,包括电子束强度的调整、图像亮度以及对比度的调整、图片标尺的显示和标定、电子衍射分析图片采集、特殊情况下样品观察和图片采集、电子束过曝保护设置、荧光屏抬起和落下控制、CCD与 TEM 的通讯恢复等。

       

      Abstract: Usage skills and parameters setting of Olympus CCD installed in JEM-2100TEM were narrated,which included adjusting the intensity of electron beam,adjusting the contrast and brightness of images;scaledisplaying and calibrating;properly acquiring image in SAED;observing samples and acquiring images in specialcases;protective setting of over-exposure;controlling the putting up and down of the fluorescent screen;restoringthe communication between CCD and TEM,etc.

       

    /