高级检索

    锅炉水冷壁管爆管分析

    Rupture Analysis of Boiler Water-wall Tube

    • 摘要: 通过化学成分分析、力学性能测试、宏观和微观检验等方法,对锅炉水冷壁管爆管事故的原因进行了分析。结果表明: 该水冷壁管是由于过热造成珠光体球化而导致材料性能下降,因此发生了爆管。

       

      Abstract: Rupture reason of boiler water-wall tube was analyzed by means of chemical composition analysis, mechanical properties testing, macroscopic and microscopic examination. The results showed that the rupture of the water-wall tube was as a result of material performance degradation caused by pearlite spheroidization under overheating condition.

       

    /

    返回文章