高级检索

    涂层材料热传导性能测试标准比较

    Comparison of test standards for thermal conductivity of coating materials

    • 摘要: 选取了两种典型的核电涂层材料,分别采用普通热流计法、护热式热流计法以及闪光法对材料进行热传导率测试。结果表明:闪光法与热流计法在无机锌涂层测试中存在较大误差,无法替代ASTM E1530标准中的方法;两种热流计法测得的结果接近,但仍存在30%~50%的偏差;在环氧涂层的测试中,3种方法所得结果较为接近。鉴于现行标准未对关键变量进行明确规定,建议制定核电涂料专用的国家标准,以提高测试结果的准确性和一致性。研究结果可为涂层材料测试标准化提供重要参考。

       

      Abstract: Two typical nuclear power coating materials were selected, and the thermal conductivity of the materials was tested by ordinary heat flow meter method, heat protection heat flow meter method and flash method respectively. The results show that there was a big error between the flash method and the heat flow meter method in the test of inorganic zinc coating, which could not replace the method of ASTM E1530 standard. The results measured by the two heat flow meter methods were close, but there were still 30%—50% deviations. In the test of epoxy coating, the results obtained by the three methods were relatively close. In view of the fact that the current standards did not specify the key variables, it was recommended to develop a national standard for nuclear power coatings to improve the accuracy and consistency of test results. The research results could provide an important reference for the standardization of coating material testing.

       

    /