    超临界电站磨煤机12.9级高强度螺栓断裂原因

    Reasons for fracture of grade 12.9 high strength bolt of coal mill in supercritical power station

    • 摘要: 某磨煤机用12.9级高强度螺栓发生断裂现象,采用宏观观察、扫描电镜分析、化学成分分析、金相检验、力学性能测试等方法对断裂原因进行分析。结果表明:该高强度螺栓的断裂性质为线源疲劳断裂,疲劳源位于螺纹牙底应力集中处;高强度螺栓调质处理时的回火温度偏高,使螺栓强度低于标准要求,最终导致螺栓断裂。

       

      Abstract: The fracture phenomenon of 12.9 grade high strength bolt for a coal mill occurred. The reasons of the fracture bolt was analyzed by means of macroscopic observation, scanning electron microscope analysis, chemical composition analysis, metallographic examination and mechanical property test. The results show that the fracture property of the high strength bolt was line source fatigue fracture, and the fatigue source was located at the stress concentration of the thread bottom. The tempering temperature of high strength bolts during quenching and tempering was high, which made the strength of bolts lower than the standard requirements, and finally led to the fracture of bolts.

       

    /