    42CrMo钢管接头断裂原因

    Fracture reason of 42CrMo steel pipe joint

    • 摘要: 某公司生产的42CrMo钢功能性接头在安装过程中发生断裂现象,采用宏观观察和扫描电镜分析、化学成分分析、金相检验、力学性能测试等方法分析其断裂原因。结果表明:该接头断裂性质属于脆性断裂,材料原始组织偏析严重,热处理后材料质量和韧性不好,冲击试验结果不能满足设计要求;在接头组装过程中,其内外螺纹没有水平对正,在安装过程中承受异常载荷,接头最终发生断裂。

       

      Abstract: The fracture of 42CrMo steel functional joint produced by a company occurred during installation. The fracture reasons were analyzed by means of macroscopic observation and scanning electron microscope analysis, chemical composition analysis, metallographic examination and mechanical property test. The results show that the fracture property of the joint was brittle fracture, the segregation of the original structure of the material was serious, the quality and toughness of the material after heat treatment were not good, and the impact test results could not meet the design requirements. During the assembly process of the joint, the internal and external threads were not horizontally aligned, and they were subjected to abnormal loads during the installation process, and eventually broke.

       

    /