    某电厂锅炉水冷壁管壁厚异常减薄原因

    Causes of abnormal wall thickness thinning of boiler water wall in a power plant

    • 摘要: 在某电厂水冷壁管的防磨、防爆检查过程中,发现大批量水冷壁管壁厚发生异常减薄现象。采用宏观观察、化学成分分析、力学性能测试、金相检验、扫描电镜和能谱分析等方法对壁厚异常减薄原因进行分析。结果表明:水冷壁管向火侧管壁异常减薄的主要原因是向火侧管壁发生硫化物高温腐蚀,最终导致水冷壁管壁厚异常减薄。

       

      Abstract: In the process of anti-wear and explosion-proof inspection of water wall tubes in a power plant, it was found that the wall thickness of a large number of water wall tubes was abnormally thinned. The causes of abnormal wall thickness thinning were analyzed by means of macroscopic observation, chemical composition analysis, mechanical property test, metallographic examination, scanning electron microscopy and energy spectrum analysis. The results show that the main reason for the abnormal thinning of the water wall tube to the fire side was the high temperature corrosion of the sulfide on the fire side tube wall, which eventually led to the abnormal thinning of the water wall tube wall thickness.

       

    /