高强度螺柱断裂原因
Fracture reason of high strength stud
-
摘要: 某高强度螺柱在服役10个月后发生断裂,采用宏观观察、化学成分分析、扫描电镜分析、金相检验以及力学性能测试等方法对螺柱断裂原因进行了研究。结果表明:在较大交变载荷的作用下,断裂螺柱螺纹牙底的折叠位置萌生裂纹并扩展,最终发生疲劳断裂。Abstract: The high strength stud was fractured after 10 months of service. The causes of stud fracture were studied by means of macroscopic observation, chemical composition analysis, scanning electron microscope analysis, metallographic examination and mechanical property test. The results show that under the action of large alternating load, cracks initiated and propagated at the folding position of the screw thread bottom of the fractured stud, and finally fatigue fracture occured.